Tuesday, April 24, 2007

(Trainer) Diagram Options Details

This is a detailed list of the restrictions/limitations (also known as diagram options) that can be imposed on each diagram by the trainer. There are three areas of diagram options; Environment, Editing and Simulation.

------------------------------------
Environment Options
------------------------------------

Diagram Editing Access Level
-
Allow full editing of the diagram
-Allow limited editing of the diagram
-No editing


Circuit Simulation Access Level
-Allow full circuit simulation
-Allow limited circuit simulation
-No circuit simulation

Power Flow
-Display the power flow in the circuit during simulation

Screen
-Allow splitting the screen

Zooming
-Allow zooming

Grid Layer
-Allow the VISIBLE status to be changed
-Allow the LOCK status to be changed

Drawing Layer

-Allow the VISIBLE status to be changed
-Allow the LOCK status to be changed

Sound Effects

-Allow turning the sound effects ON or OFF
-Allow setting up the sound effects
-Allow changing the sound effects volume levels

Symbol Library

-Display the symbol library at start-up

Panel Buttons
-Allow using the panel buttons
-Allow editing the panel buttons
-Display the panel button window at start-up

Saving
-Allow saving bitmap clips of the diagram

Printing
-Allow printing the diagram
-Allow changing the printer settings
-Allow printing the general information report
-Allow printing the technical information report

Simulation Log
-Create a simulation log
-Allow displaying the simulation log form

Editing
-Allow copying and pasting

Drawing Tools
-Allow adding lines
-Allow adding circles
-Allow adding ellipses
-Allow adding boxes
-Allow adding rounded boxes
-Allow adding rectangles
-Allow adding rounded rectangles
-Allow adding text boxes

Legends
-Allow adding a new legend to the diagram
-Allow modifying the existing legend in the diagram

Templates
-Allow templates to be loaded in the diagram
-Allow templates to be saved

Symbols
-Allow new symbols to be added
-Allow using the line filling options
-Allow highlighting the symbols that are assigned or grouped
-Display pop-up information for symbols that are assigned or grouped

Power Points
-Allow new power points to be added

Transformers
-Allow transformers to be added

PLC I/O Modules
-Allow PLC I/O modules to be added

Terminal Strip Modules
-Allow terminal strips to be added

Soft Starter Modules
-Allow soft starter modules to be added

Variable Speed Modules
-Allow variable speed modules to be added

Wire Cross-Overs
-Allow the cross-over style to be changed

Renumbering
-Allow using the RENUMBER feature

Diagram Layout Format (DLF)
-Allow changing the diagram layout format (spacing, fonts, etc.)


------------------------------------
Editing Options
------------------------------------
Drawing Tools
-Allow modifying existing drawing objects

Empty Symbol Cells
-Allow moving the connecting lines
-Allow deleting the connecting lines
-Allow changing the connecting lines
-Allow adding symbols

Symbol Lines
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the connecting lines

Inactive Symbols
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines

Rung Numbers
-Allow moving
-Allow deleting
-Allow setting the options
-Allow using the RUNG NUMBER FILL feature

Contact Locations
-Allow moving
-Allow deleting

Power Points
-Allow moving
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow changing the power flow color
-Allow converting the power points

Transformers
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the wire id text
-Allow changing the connection label text
-Allow changing the power flow color

PLC I/O Modules
-Allow moving
-Allow deleting
-Allow changing the label text

Terminal Stip Modules
-Allow moving
-Allow deleting
-Allow changing the label text

Soft Starter Modules
-Allow moving
-Allow deleting
-Allow changing the label text

Variable Speed Modules
-Allow moving
-Allow deleting
-Allow changing the label text

Relays (two wire coil)
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow changing the delay settings
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display information about the relay

Relays (three wire coil)
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow changing the delay settings
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display information about the relay
-Alternating Relays - Allow the trigger mode to be changed

Relays (four wire coil)
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow changing the delay settings
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display information about the relay
-Alternating Relays - Allow the trigger mode to be changed

Counters
-Allow the counter to be rotated
-Allow the counter to be moved
-Allow the counter to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow the SET number to be changed
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display information about the counter


Indicators
-Allow the indicator to be rotated
-Allow the indicator to be moved
-Allow the indicator to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines"
-Allow setting to DEFECTIVE OPEN
-Allow setting to DEFECTIVE SHORTED
-Display information about the indicator

Horns/Buzzers
-Allow the horn to be rotated
-Allow the horn/buzzer to be moved
-Allow the horn/buzzer to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display information about the horn/buzzer

Motors
-Allow the motor to be rotated
-Allow the motor to be moved
-Allow the motor to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow setting the windings to DEFECTIVE OPEN
-Allow setting the windings to DEFECTIVE SHORTED
-Allow setting the motor to DEFECTIVE LOADED
-Allow setting the motor to DEFECTIVE LOCKED
-Display information about the motor

Switches
-Allow the switch to be rotated
-Allow the switch to be moved
-Allow the switch to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow a switch to be assigned for use in associated reaction
-Allow a switch to be added to a group
-Allow the state of a switch to be manually changed
-Allow the state of a switch to be locked
-Display the activated state of a switch
-Display information about the switch

Contacts
-Allow the contact to be rotated
-Allow the contact to be moved
-Allow the contact to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow contacts to be assigned
-Allow the state of a contact to be manually changed
-Allow the state of a contact to be locked
-Display the activated state of a contact
-Display information about the contact

Pushbutton Control Heads
-Allow the control head to be rotated
-Allow the control head to be moved
-Allow the control head to be deleted
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow the control head to be LOCKED
-Allow the state of the control head to be changed
-Display information about the control head

Multi-Position Switch Control Heads
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the description text

-Allow changing the control head position
-Allow changing the contact configuration
-Display information about the control head

Common Points
-Allow rotating
-Allow moving
-Allow deleting
-Allow changing the description text
-Allow changing the wire id text
-Allow changing the terminal id text
-Allow changing the connecting lines
-Allow adding to a group

------------------------------------
Simulation Options
------------------------------------
Relays (two wire coil)
-Allow setting the coil to DEFECTIVE OPEN"
-Allow setting the coil to DEFECTIVE SHORTED
-Display the energized and timing states
-Display the remaining ON/OFF delay times
-Display a label that shows the status of the coilRelays (three wire coil)

Relays (three wire coil)
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display the energized and timing states
-Display the remaining ON/OFF delay times
-Display a label that shows the status of the coil
-Alternating Relays - Allow the relay to be locked in either of the two positions

Relays (four wire coil)
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED"
-Display the energized and timing states
-Display the remaining ON/OFF delay times
-Display a label that shows the status of the coil
-Alternating Relays - Allow the relay to be locked in either of the two positions

Counters
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED

-Display the energized state

Indicators
-Allow to be set as defective OPEN
-Allow to be set as defective SHORTED
-Display a label that shows the status of the indicator
-Display the energized state

Horns/Buzzers
-Allow setting the coil to DEFECTIVE OPEN
-Allow setting the coil to DEFECTIVE SHORTED
-Display a label that shows the status of the horn/buzzer
-Display the energized state

Motors
-Allow the windings to be set as defective OPEN
-Allow the windings to be set as defective SHORTED
-Allow the motor to be set as defective LOADED
-Allow the motor to be set as defective LOCKED
-Display the energized states
-Display a label that shows the status of the motor

Switches
-Allow a switch to be LOCKED
-Allow the state of a switch to be changed
-Display the remaining ON/OFF time delays
-Display a label that shows the status of the switch
-Display the activated state of the switch

Contacts
-Allow a contact to be LOCKED
-Allow the state of a contact to be changed
-Display a label that shows the status of the contact
-Display the activated state of the contact

Pushbutton Control Heads
-Allow the control head to be LOCKED
-Display a label that shows the status of the pushbutton

Multi-Position Switch Control Heads
-Allow the control head position to be changed

0 comments: